As accessibility becomes a growing priority for architects, builders, and communities, adult changing tables are increasingly being addressed in building codes and legislation across the United States and Canada. In Canada, the 2020 National Building Code of Canada (NBC) helps guide the design of safer, more accessible, and inclusive spaces by establishing model building standards, including requirements for adult changing tables in certain public buildings.

Read on to explore the NBC 2020 adult changing table requirements, including which buildings are affected, key design specifications, and what you need to know to create more accessible, code-compliant public washrooms across Canada.

What is the NBC?

The National Building Code of Canada (NBC) is a model code that establishes a consistent framework for building safety, accessibility, and construction standards across Canada. As a model code, the NBC serves as a national reference rather than a law that automatically applies throughout the country. Each province and territory is responsible for adopting and enforcing its own building regulations, which may incorporate the NBC in full, adopt certain provisions, or introduce additional requirements.

This means that while the NBC provides a foundation for adult changing table requirements across Canada, specific regulations and enforcement timelines may vary by province or territory. Architects, designers, and facility owners should always consult their local building codes to ensure compliance.

Universal changing table

What Buildings are Required to Have Adult Changing Tables in Canada?

At least one accessible changing space is required when a building contains one of the following major occupancies with an occupant load exceeding 500 people: 

Occupancy Group  Occupancy Type Examples
Group A Assembly Arenas, stadiums, theatres, convention centers, large recreation facilities
Group B, Division 2 Treatment Hospitals and certain medical treatment facilities
Group 5 Mercantile  Large retail stores and shopping centers

Person in a wheelchair interacting with a modern bathroom setup.

Universal Changing Table Requirements in Canada

For buildings that fall under Group A, Group B Division 2, or Group E occupancy classifications and meet the applicable occupant load threshold, the NBC outlines specific requirements for adult changing stations. Here's a breakdown of the key requirements: 

Accessible Location

The changing table must be located on the same floor as the building’s main accessible entrance.

Universal Washroom

The table must be installed in a universal washroom designed to accommodate users of varying abilities and needs.

Space for the Table

A minimum clear floor space of 810 mm × 1,830 mm must be provided for the table, without overlapping required wheelchair turning or toilet transfer areas.

Transfer Space

A clear space of at least 900 mm × 1,350 mm must be available along the long side of the table to allow for easier transfers.

Wheelchair Maneuverability

The universal washroom must provide a minimum turning space of 1,700 mm in diameter to accommodate wheelchair users. 

Attend Adult Changing Table open in a modern bathroom

Building a More Accessible Canada

As accessibility standards continue to evolve across Canada, understanding adult changing table requirements is an important step toward creating more inclusive public spaces. 

At Sova, we're committed to helping facilities create accessible washrooms that accommodate people of all ages and abilities. Explore our adult changing table solutions to find the right fit for your facility and take the next step toward building a more inclusive Canada.